| BGW Professional Model 200 Specifications |
| IHF Method 4% Duty Cycle Burst Power |
Bridged Mono |
Dual Channel |
| 8 ohms |
490W |
160 W/ch |
| 4 ohms |
|
245 W/ch |
| Intermodulation Distortion |
less than 0.02% at rated 8 ohm power output
(SMPTE method, 60 Hz & 7 kHz, 4:1 ratio) |
| Rise Time |
4 µs |
| Slew Rate |
20 V/µs (stereo mode), 40 V/µs (mono mode) |
| Damping Factor |
> 400:1 (ref. 8 ohms) below 1 kHz |
| Small Signal Frequency Response |
1 Hz - 85 kHz, +0/-3 dB
20 Hz - 20 kHz, +0,-0.25 dB |
| Crosstalk |
> 70 dB @ 20 Hz - 20 kHz |
| DC Offset Voltage |
<±10 mV (3 mV typical) |
Hum & Noise Level
8 ohms 20 Hz - 20 kHz |
> 103 dB < 100 W (unwtd.) bal. |
| Voltage Gain |
X 31.6 = 30 dB |
Input Impedance
@ 8 ohm rated power |
15k ohms & 240 pF bal. or unbal.
(balance input between pin 2 & 3) |
| Input Sensitivity |
0.90 Vrms for rated 8 ohm output |
| Load Impedance |
>= 8 ohms (stereo mode)
<= 16 ohms (mono mode) |
| Power Requirement |
400 W for rated 8 ohms,
100, 120, 200, 220 or 240 V AC, 50-60 Hz |
| Dimensions |
| overall (h x w x d) |
1.75 X 19 X 11.9 (inches) |
behind front panel (h x w x d) |
1.75 X 17 X 11 (inches) |
| Weight |
14 lbs (6.4 kg.) net, 19 lbs (8.6 kg.)
shipping |
| Control |
One position detented rotary control
precision input attenuator per channel. Attenuation steps of 0, -2 through -30 dB
(2 dB steps), -33, -36, -42, -50, -60 |
| Switches |
pwr/mag circuit breaker
bridged operation switch
ground lift switch |
| Option |
06 balanced transformers |
| Phase Shift |
20 Hz - 20 kHz &plsmn; 10° |
| Polarity Convention |
XLR pin 2 hot/tip, pin 3 -/ring,
pin 1 ground/sleeve |
| Warranty |
3 Years standar, parts/labor |
| ProNet Price |
$ 999.00 |
| Applications |
Recording/Post Production,
Broadcast |